Pre pinch
Pre pinch - Closing off an open end of the parison, before the molds pinch is together. Often used in connection with pre blow.
Pre blow in extrusion blow molding
Pre Blow - The injection of a medium into a closed parison before the molds close.
Parison mechanical or electronic Programming
Mechanical or Electronic Programming - A method of changing the shape and wall thickness during formation of the parison.
Setting up manual cycle in injection molding
Manual cycle - A manual cycle requires that each machine function be controlled manually by an operator.
Low pressure injection mold close
Low pressure mold close - Low pressure mold closing is a provision in the machine to lower the clamp closing force during the clamp closing cycle. The lower clamp forces minimizes the danger of mold damage caused by parts caught between the mold faces.
Die and pin set extrusion blow molding
Die and Pin Set - A matching ring and pin to form a parison of a given shape.
Design of experiments, DOX, DOE in extrusion blow molding
A statistical design of experiments, or DOX, is the preferred method to determine an optimum blow molding process and processing window. Initial mold/process evaluations should be completed on a small prototype mold when possible. The mold is normally shipped from the tool builder to the molder's development laboratory. The molder's development laboratory should have the time and resources available to evaluate the molding process for that mold and to perform any initial Design of Experiments.
The objective of a design of experiments is to not only identify an optimum process and processing window, but also to identify the main effects from process variables, interactions between them, and possible curvature effects. Initial experiments are run to determine which combination of process control parameters yields the lowest dimensional variability. Once this is determined, the tool steel can be adjusted to meet the molded container dimensional specifications. It is important NOT to choose process control parameters solely based on the part specifications. If your tool builder constructs the mold using a "Steel Safe" approach, you will be able to easily cut and ‘adjust’ the steel for the most stable and efficient process.
It is recommended that the Design of Experiments be performed on the blow molding machine on which the mold will run on during production or sampling. Only a skilled molding company can accurately translate the process control parameters from one blow molding machine to another. Even if the machines are similar, there are always differences that will affect the attributes of the molded part. The amount of wear on the extruder, the mold clamp system design, hydraulic valves, screw, barrel and timers can differ and can have large effects on process control parameter adjustments. In addition, the molder’s development laboratory often utilizes a different (mold) cooling system than the system used in a manufacturing area. Differences in development laboratory (individual mold temperature control systems) and manufacturing plant (central) coolant system performance can be significant. Careful attention must be given to the actual cooling (heat transfer) variables in the mold.
The objective of a design of experiments is to not only identify an optimum process and processing window, but also to identify the main effects from process variables, interactions between them, and possible curvature effects. Initial experiments are run to determine which combination of process control parameters yields the lowest dimensional variability. Once this is determined, the tool steel can be adjusted to meet the molded container dimensional specifications. It is important NOT to choose process control parameters solely based on the part specifications. If your tool builder constructs the mold using a "Steel Safe" approach, you will be able to easily cut and ‘adjust’ the steel for the most stable and efficient process.
It is recommended that the Design of Experiments be performed on the blow molding machine on which the mold will run on during production or sampling. Only a skilled molding company can accurately translate the process control parameters from one blow molding machine to another. Even if the machines are similar, there are always differences that will affect the attributes of the molded part. The amount of wear on the extruder, the mold clamp system design, hydraulic valves, screw, barrel and timers can differ and can have large effects on process control parameter adjustments. In addition, the molder’s development laboratory often utilizes a different (mold) cooling system than the system used in a manufacturing area. Differences in development laboratory (individual mold temperature control systems) and manufacturing plant (central) coolant system performance can be significant. Careful attention must be given to the actual cooling (heat transfer) variables in the mold.
In Mold Labeling IML setup procedure
The IML system must be adjusted to accommodate the mold cavities, label size, and label position on the container. The adjustments must be done in relation to the molds, with the proper placer arm assembly, vacuum cup heads, and label magazines installed.
Procedure for Shuttle Process:
A. Carriage and Placer Arm Assembly Setup
1. Adjust the carriage and placer arm assembly. Disconnect the actuator links from the front and back sides of the placer arm assembly at the drag links.
2. Check that the angle between actuator arms and the top of the carriage frame is 75 degrees.
3. On the cylinder side only, reconnect the actuator links to the drag link. Check to assure the actuator arm is still in contact with the latch link. Adjust the link as required so that the placer arms are flat against the placer arm bracket and the actuator arm is against the latch link. Adjust the opposite (non cylinder) side, similarly. It is important to ‘balance’ the force on both the front and back side of the actuator links, taking care not to put a
‘jacking force’ on the components.
B. Centering the Placer Arm Assemblies Horizontally Between the Molds
1. Assure adequate daylight opening between mold halves exist on both side A and side B. Back-off the deployment roller (move towards the mold).
2. Move the placer arm assembly between the mold halves to the full in position and set the carriage lock.
3. Loosen the (4) screws that bolt the slide base to the upper frame.
4. Measure the distance from the inside face of the placer arm to the front face of the mold. Repeat the procedure on back face of the mold. If the measurement is not the same turn the adjustment screw located on the upper frame and below the slide base. The placer arm assembly is centered when this distance is the same on both the front and back halves of the mold.
5. Retighten the (4) screws on the slide base.
C. Centering the Vacuum Heads Vertically in the Cavity
1. Back off the deployment roller on the lift-up cam.
2. Move the inserter carriage between the mold halves to the full in position and set the carriage lock.
3. Slightly loosen the (4) screws on the back of the lower frame.
4. Turn the adjustment jackscrew: clockwise to raise, counterclockwise to lower.
5. Check to assure the vacuum cup head is approximately centered vertically in the cavity.
6. Retighten (4) screws.
7. Release the carriage lock and move the carriage out and in by hand to insure that no part of the placer arm interferes with the mold cavities or platen tie rod as it is lifted up into position. Readjust as required, then reset carriage lock to continue.
D. Setting the Tow Bar Length
1. With the placer arm ‘in molds’ and carriage lock engaged, loosen tow bar jam nuts (R.H. and L.H. nuts).
2. While manually extending placer arms, turn the tow bar until vacuum cups are located in the mold cavities as required, usually centered in the label panel area.
3. Tighten the jam nuts.
E. Adjusting the Deployment Roller
1. Assure the carriage lock is engaged.
2. Loosen the lock screw on front of the deployment roller housing.
3. Turn the adjustment screw: clockwise to extend vacuum cups deeper (moves roller away from molds); counterclockwise to retract arms (moves roller towards molds).
4. Check vacuum cup centering, readjust as required.
5. Retighten the lock screw. Placer arm extension should allow for only slight flattening of the vacuum cups against the walls of the mold. Over extension and excessive force may cause excessive wear and premature failure of the placer arm assembly components.
F. Adjusting the Label Magazines
1. Unlock and open the door of the magazine guard.
2. Pull back the pusher plate while holding the remaining stack upright.
3. Load new labels in until desired amount is reached.
4. While releasing pressure on the pusher plate shuffle stack down into and even stack.
5. Close and lock the magazine guard door. Label stacks should be ‘riffled’ several times to eliminate ‘edge welding’ due to die cutting and to allow some air to become entrapped between labels.
6. Set the label stops to allow the labels to be picked easily without double picking or moving the next label out of position. The overlap of the stops onto the label may be different from side to side or top to bottom. The overlap should be about 1/16” initially.
7. Adjust the magazine position (amount of contact force) between the label stack and the vacuum cup heads by moving the magazines in and out. Loosen the lock-down collars and release the lock-down clamp that holds the magazine in place.
8. With the blow molding machine and IML system in ‘Manual’ mode, press the ‘Step/Home’ button to move the first pair of placer arms to the first label pick position. Note how the vacuum cups contact the end label on the stack in the magazine.
9. Adjust the label magazine in or out as required to achieve proper contact. Secure lock-down collars after proper magazine position is achieved.
G. Pick Cylinder Speed
1. Ensure that adequate plant air pressure is available.. Adjust the regulator located on the pneumatic control assembly to 80 psi.
2. Adjust extension speed of the placer arms on valve connected to rod end of cylinder, turn stem: clockwise to slow; counterclockwise to speed up.
3. To adjust retraction speed of the placer arms turn valve connected to other end of cylinder do likewise.
H. Pick and Mold Vacuum
1. The IML system vacuum pumps require 80 psi for optimum performance. Adjust the pick vacuum with the regulator located on the pneumatic control assembly. Settings lower than 60 psi may result in missed picks.
2. Adjust mold vacuum with the regulator located on the pneumatic control assembly. Mold vacuum requirements will vary depending on the number of vacuum ports in the mold, label materials, container shape, etc.
I. Adjusting Label Position on Container
1. The adjustments are side to side, height, and skew (rotation). Adjust the label position by loosening the appropriate clamps and moving the adjustments in direct relation to the container. Retighten clamps to prevent changes in settings due to vibration.
J. Setting Up and Modifying Programs
1. Refer to the IML operating instructions manual for specific program modifications. The number of picks and the position of label picking are normally modified whenever the number of cavities or cavity spacing is changed. No other program modifications are normally required.
Procedure for Shuttle Process:
A. Carriage and Placer Arm Assembly Setup
1. Adjust the carriage and placer arm assembly. Disconnect the actuator links from the front and back sides of the placer arm assembly at the drag links.
2. Check that the angle between actuator arms and the top of the carriage frame is 75 degrees.
3. On the cylinder side only, reconnect the actuator links to the drag link. Check to assure the actuator arm is still in contact with the latch link. Adjust the link as required so that the placer arms are flat against the placer arm bracket and the actuator arm is against the latch link. Adjust the opposite (non cylinder) side, similarly. It is important to ‘balance’ the force on both the front and back side of the actuator links, taking care not to put a
‘jacking force’ on the components.
B. Centering the Placer Arm Assemblies Horizontally Between the Molds
1. Assure adequate daylight opening between mold halves exist on both side A and side B. Back-off the deployment roller (move towards the mold).
2. Move the placer arm assembly between the mold halves to the full in position and set the carriage lock.
3. Loosen the (4) screws that bolt the slide base to the upper frame.
4. Measure the distance from the inside face of the placer arm to the front face of the mold. Repeat the procedure on back face of the mold. If the measurement is not the same turn the adjustment screw located on the upper frame and below the slide base. The placer arm assembly is centered when this distance is the same on both the front and back halves of the mold.
5. Retighten the (4) screws on the slide base.
C. Centering the Vacuum Heads Vertically in the Cavity
1. Back off the deployment roller on the lift-up cam.
2. Move the inserter carriage between the mold halves to the full in position and set the carriage lock.
3. Slightly loosen the (4) screws on the back of the lower frame.
4. Turn the adjustment jackscrew: clockwise to raise, counterclockwise to lower.
5. Check to assure the vacuum cup head is approximately centered vertically in the cavity.
6. Retighten (4) screws.
7. Release the carriage lock and move the carriage out and in by hand to insure that no part of the placer arm interferes with the mold cavities or platen tie rod as it is lifted up into position. Readjust as required, then reset carriage lock to continue.
D. Setting the Tow Bar Length
1. With the placer arm ‘in molds’ and carriage lock engaged, loosen tow bar jam nuts (R.H. and L.H. nuts).
2. While manually extending placer arms, turn the tow bar until vacuum cups are located in the mold cavities as required, usually centered in the label panel area.
3. Tighten the jam nuts.
E. Adjusting the Deployment Roller
1. Assure the carriage lock is engaged.
2. Loosen the lock screw on front of the deployment roller housing.
3. Turn the adjustment screw: clockwise to extend vacuum cups deeper (moves roller away from molds); counterclockwise to retract arms (moves roller towards molds).
4. Check vacuum cup centering, readjust as required.
5. Retighten the lock screw. Placer arm extension should allow for only slight flattening of the vacuum cups against the walls of the mold. Over extension and excessive force may cause excessive wear and premature failure of the placer arm assembly components.
F. Adjusting the Label Magazines
1. Unlock and open the door of the magazine guard.
2. Pull back the pusher plate while holding the remaining stack upright.
3. Load new labels in until desired amount is reached.
4. While releasing pressure on the pusher plate shuffle stack down into and even stack.
5. Close and lock the magazine guard door. Label stacks should be ‘riffled’ several times to eliminate ‘edge welding’ due to die cutting and to allow some air to become entrapped between labels.
6. Set the label stops to allow the labels to be picked easily without double picking or moving the next label out of position. The overlap of the stops onto the label may be different from side to side or top to bottom. The overlap should be about 1/16” initially.
7. Adjust the magazine position (amount of contact force) between the label stack and the vacuum cup heads by moving the magazines in and out. Loosen the lock-down collars and release the lock-down clamp that holds the magazine in place.
8. With the blow molding machine and IML system in ‘Manual’ mode, press the ‘Step/Home’ button to move the first pair of placer arms to the first label pick position. Note how the vacuum cups contact the end label on the stack in the magazine.
9. Adjust the label magazine in or out as required to achieve proper contact. Secure lock-down collars after proper magazine position is achieved.
G. Pick Cylinder Speed
1. Ensure that adequate plant air pressure is available.. Adjust the regulator located on the pneumatic control assembly to 80 psi.
2. Adjust extension speed of the placer arms on valve connected to rod end of cylinder, turn stem: clockwise to slow; counterclockwise to speed up.
3. To adjust retraction speed of the placer arms turn valve connected to other end of cylinder do likewise.
H. Pick and Mold Vacuum
1. The IML system vacuum pumps require 80 psi for optimum performance. Adjust the pick vacuum with the regulator located on the pneumatic control assembly. Settings lower than 60 psi may result in missed picks.
2. Adjust mold vacuum with the regulator located on the pneumatic control assembly. Mold vacuum requirements will vary depending on the number of vacuum ports in the mold, label materials, container shape, etc.
I. Adjusting Label Position on Container
1. The adjustments are side to side, height, and skew (rotation). Adjust the label position by loosening the appropriate clamps and moving the adjustments in direct relation to the container. Retighten clamps to prevent changes in settings due to vibration.
J. Setting Up and Modifying Programs
1. Refer to the IML operating instructions manual for specific program modifications. The number of picks and the position of label picking are normally modified whenever the number of cavities or cavity spacing is changed. No other program modifications are normally required.